About Daikin fan coils
Origin: Japan (Daikin Industries). In Türkiye: Fan coils are produced at the plant in Hendek, Sakarya.
Daikin fan coil series we service
- FWG, FWC, FWF, FWK (cassette)
- FWZ, FWV (floor-standing)
- FWR, FWL, FWE, FWS, FWM (floor/ceiling)
- FWT (wall-mounted)
- FWA, FWP, FWB, FWD (ducted)
Unit types
Service highlights
- Versions with BLDC motors
- Multi-speed motor on the FWB series
- 360° air discharge and condensate pump on the FWC cassette
Our services for Daikin fan coils
Daikin fan coil maintenance
Checks of filters, coil, drain pan, drainage, fan, valves and thermostat; documented periodic maintenance.
Daikin fan coil faults and repair
On-site repair of water leaks, no cooling, fans not turning, valve and controller faults.
Cleaning and filters
Chemical coil washing, drain pan disinfection, filters cut to size.
Daikin fan coil spare parts
Supply and fitting of compatible motors, valves, thermostats, pumps and other parts.
Daikin fan coil error codes
FWT wall-mounted, FWC cassette, FWF and FWG series (wired controller display)
When an abnormality occurs, the wired controller shows the error code by flashing it.
| Code / indication | Meaning | What to do |
|---|---|---|
| E1 | Room (ambient) temperature sensor fault: open or short circuit | Check the sensor connector and cable; replace the sensor if necessary. |
| E2 | Water pipe / coil temperature sensor fault | Measure the sensor connection and resistance; replace the sensor if necessary. |
| E4 | Water temperature not suitable (weak) | Check the chiller or boiler supply water, the valve and circulation. |
| E5 | Water temperature incorrect | Check the water supply, the 3-way valve and the heating/cooling mode selection. |
| E6 | Drain (condensate) pump fault (cassette) | Clean the drain line and float switch, and test the pump. |
| E8 | Hardware error: button on the board short-circuited | The display or control board must be replaced. |
| E9 | No feedback from the indoor unit fan motor (FWT) | Check the fan motor connector; replace the motor or the board. |
European series (FWV, FWL, FWM, FWZ, FWR, FWS, FWB, FWD) – FWEC control board
This series has no numbered error codes. If the water temperature does not suit the mode (e.g. lukewarm water in cooling mode), the mode symbol on the controller flashes. Fix: check the chiller/boiler and the water temperature.
Sources: document 1, document 2, document 3
Common thermostat warnings
Warnings shown on Siemens RDF series thermostats, which are often used with Daikin fan coils:
| Indication | Meaning | What to do |
|---|---|---|
| AL1 | External fault input X1 active (e.g. drain alarm) | Check the device connected to input X1. |
| AL2 | External fault input X2 active | Check the device connected to input X2. |
| FIL | Filter cleaning reminder | Clean the filter and reset the warning. |
| Dew (condensation) symbol | Condensation detected in the room, cooling stopped | Check humidity and water temperature. |
Is your Daikin fan coil showing a code?
Send a photo of the controller display and the unit's rating label and we will interpret it right away.
Daikin fan coil controllers and thermostats
BRC315D7
Wired · for FWC and FWF series
BRC7E530 / BRC7F532F
Wireless (IR) · Heating + cooling
BRC7E531 / BRC7F533F
Wireless (IR) · Cooling only
BRC51D67
Wireless · FWT wall-mounted
FWEC series
Wired wall controller + board · European series fan coils
DCS302CA51 / DCS601C51C
Central controller · Multi-unit management
In addition to these controllers, we replace faulty or outdated thermostats with new models suited to the unit's 2/4-pipe configuration, valve type and motor speeds: mechanical, digital, weekly programmable and Modbus / BACnet / KNX networked options. Thermostat options →
Daikin fan coil spare parts
Daikin fan coil motor
Compatible part supply and fitting
Daikin capacitor
Compatible part supply and fitting
Daikin fan wheel
Compatible part supply and fitting
Daikin motorized valve
Compatible part supply and fitting
Daikin actuator
Compatible part supply and fitting
Daikin thermostat
Compatible part supply and fitting
Full spare parts catalog (28 parts) →
Daikin fan coil service in Ankara
We service Daikin fan coils on-site in every district of Ankara. We prepare bulk maintenance plans for office towers, hospitals, hotels, schools, shopping malls and residential complexes. For Daikin units outside Ankara, we start with a pre-diagnosis from photos and videos, followed by a scheduled visit with the required parts.
Fan coil service for other brands
Aldağ fan coil service
Üntes fan coil service
Carrier fan coil service
Form fan coil service
Systemair fan coil service
Mitsubishi Electric fan coil service
Arçelik fan coil service
Ventas fan coil serviceTeknogenTeknogen fan coil service
Trane fan coil serviceFrequently asked questions
Do you service Daikin fan coils on-site in Ankara?
Yes. Our base is in Etimesgut; we carry out on-site maintenance, fault repair and part replacement on Daikin fan coils in every district of Ankara. For Daikin units outside Ankara we provide scheduled service across Türkiye.
Are you the authorized Daikin service?
No. YOİ Mühendislik is an independent service holding the TSE Service Adequacy Certificate (HYB No: 12850); we service all brands, including Daikin, independently of the manufacturer. For units still under warranty, we recommend checking the manufacturer's terms first.
What does a Daikin fan coil error code mean?
This page lists Daikin fan coil codes compiled from manufacturer documentation. Codes may vary by model and controller; send us a photo of the code on the display and we will interpret it.
Are Daikin fan coil spare parts available?
For parts such as motors, capacitors, motorized valves, actuators, thermostats, drain pans, condensate pumps, filters and fan wheels, we supply original parts that fit Daikin units or equivalents whose technical ratings match exactly. A photo of the rating label is enough.
How often should Daikin fan coils be serviced?
A full service at least twice a year, before the cooling and heating seasons; filter checks are recommended every 1–3 months depending on usage.