Home›Fan Coil Spare Parts

Fan coil spare parts catalogue

29 parts commonly needed for fan coil units: what they do, the symptoms when they fail, the technical values to check when selecting them and the part brands most often used. We supply compatible parts for all fan coil brands and can fit them for you.

  • 29 parts
  • All fan coil brands
  • Original or equivalent
  • Shipped across Turkey
In short: fan coil spare parts means matching parts such as the motor, capacitor, motorized valve and actuator, thermostat, control board, condensate pump, filter and coil to the unit's rating plate and technical values, and supplying them as original or equivalent parts. YOİ Mühendislik ships parts by courier across Türkiye or fits and tests them on site in Ankara.

Part selection also depends on the unit type; for the differences between cassette, concealed ceiling and floor-standing units, see our fan coil types guide.

The fastest way to find your part: send a photo of the unit's rating plate and the part to be replaced on WhatsApp. We match the make, model, power, dimensions and connection type, then confirm compatibility and price.

Fan and motor assembly

Fan coil motor (AC 3-speed / EC)

Drives the centrifugal blower that pushes air across the coil. Older units use 3-speed AC motors; newer ones use energy-efficient EC motors.

Failure symptoms: humming, fan not turning, overheating, thermal cut-out tripping, bearing noise, stuck on one speed.

What to check: 230 V 50 Hz, power (W), number of speeds, speed (rpm), shaft diameter and number of shafts, direction of rotation, capacitor value (µF); for EC motors, 0–10 V / PWM speed input.
ebm-papstZiehl-AbeggFergasOEM (fan coil manufacturer)
Ask about this part →
µF

Motor capacitor

Provides the phase shift a single-phase motor needs to start and run. Cheap, but one of the parts that fails most often.

Failure symptoms: motor hums but will not start, turns when pushed by hand, low speed, capacitor swollen or leaking.

What to check: capacitance (µF ±5%), operating voltage (400–450 V AC), temperature class, body diameter, connection type (stud, wire leads, spade terminals).
Ducati EnergiaOEM
Ask about this part →

Speed transformer / speed selector

Runs a single-speed motor at several speeds using different voltage taps.

Failure symptoms: some fan speeds not working, humming or a burning smell from the transformer.

What to check: power (VA/W), number of taps, input and output voltages.
Euromotors
Ask about this part →

Blower wheel / impeller

Draws air in and discharges it under pressure. Airflow drops as it gets dirty, and it becomes noisy if it loses balance.

Failure symptoms: vibration, imbalance, low airflow from dirt on the blades, cracked or broken blades.

What to check: wheel diameter × width (mm), hub and shaft diameter, direction of rotation, material (plastic/galvanised), single or double inlet.
ebm-papstFergasOEM
Ask about this part →

Blower housing (scroll)

Directs the air from the wheel and converts it into pressure.

Failure symptoms: broken clips, rubbing noise, air leakage.

What to check: model-specific part number, wheel size.
OEM
Ask about this part →

Motor mount and anti-vibration pads

Hold the motor in place and stop vibration passing into the casing and ceiling.

Failure symptoms: rattling, vibration in the casing, motor shifting out of position.

What to check: clamp diameter, rubber pad size and hardness.
OEM
Ask about this part →

Valves and water side

2-way motorized valve body

Opens or shuts off the water flow to the coil.

Failure symptoms: water does not shut off (constant heating/cooling), no water flow, stem leak, limescale.

What to check: DN15/20/25 (1/2"–1"), Kvs (m³/h), PN, threaded connection, actuator thread (e.g. M30×1.5).
WattsSiemensHoneywellBelimoDDC-TechE.C.A.
Ask about this part →
3

3-way motorized valve / 4-port valve

Diverts water either to the coil or to the bypass line, keeping the system flow rate constant.

Failure symptoms: room always cold or hot, constant flow through the bypass, leaks.

What to check: DN, Kvs, 3-way or 4-port (integrated bypass), actuator compatibility.
WattsSiemensHoneywellBelimoDDC-Tech
Ask about this part →

Valve motor / actuator

Opens, closes or modulates the valve according to the thermostat signal.

Failure symptoms: valve does not open, position indicator does not move, burnt thermoelectric element, stripped gears.

What to check: 230 V AC or 24 V AC/DC; NC (normally closed) / NO (normally open); on-off, 3-point or 0–10 V; stroke and force; connection thread; auxiliary contact.
WattsSiemensHoneywellBelimoDanfossDDC-Tech
Ask about this part →
Kv

Balancing valve (static / pressure-independent)

Ensures each fan coil receives its design flow rate, so that distant units do not get too little water and nearby ones too much.

Failure symptoms: some units heating or cooling poorly, valve noise.

What to check: DN, flow range (l/h), presetting, test points, actuator compatibility.
DanfossHoneywell
Ask about this part →

Ball valve

Isolates the unit from the pipework during servicing.

Failure symptoms: stiff handle, does not shut off fully, gland leak.

What to check: DN, PN, lever or butterfly handle, union connection, female/male thread.
Generic
Ask about this part →

Strainer (Y-type)

Protects the valve and coil from sediment and debris in the pipework.

Failure symptoms: low flow, clogged mesh, unit heating and cooling weakly.

What to check: DN, mesh size, PN.
Generic
Ask about this part →

Automatic air vent

Releases air trapped in the coil.

Failure symptoms: gurgling noise, half of the coil staying cold, dripping from the air vent.

What to check: connection size (1/8"–1/2"), maximum pressure and temperature, check valve, manual or automatic.
Caleffi
Ask about this part →

Fan coil flexible hose

Connects the unit to the pipework flexibly and without vibration, making installation easier.

Failure symptoms: leaking fittings, condensation on the insulation, corroded braiding.

What to check: 1/2" or 3/4", length, insulated/uninsulated, pressure rating.
Generic
Ask about this part →

Controls and electrics

22°

Room thermostat (mechanical, digital, BMS)

Controls the fan speed and the valve according to room temperature.

Failure symptoms: blank display, fan speed will not change, wrong temperature reading, stuck relay.

What to check: 2-pipe or 4-pipe, 3-speed or EC (0–10 V), 230 V / 24 V, valve output on-off or 0–10 V, summer/winter changeover, flush/surface mounted, weekly programme, Modbus / BACnet / KNX.
SiemensHoneywellSchneider ElectricSmallart
Ask about this part →

Room / return air sensor

Measures the temperature used by the control board.

Failure symptoms: unit never stops or never starts, error code.

What to check: sensor type (NTC 10k, PT1000 etc., must match the board), cable length, mounting method.
OEM
Ask about this part →

Water temperature sensor (minimum water / changeover)

Stops the fan, or switches the mode automatically, if the water is not hot or cold enough.

Failure symptoms: fan never starts, no mode changeover.

What to check: NTC/PTC type, pipe-clamp or immersion type.
OEM
Ask about this part →

Control board

Distributes thermostat commands to the motor speeds and the valve; on electronically controlled units it generates the error codes.

Failure symptoms: no response at all, burn marks, relay clicking, tripping fuse, error code.

What to check: manufacturer's board code, supply voltage, compatible controller.
OEM
Ask about this part →

Relays and terminals

Carry the speed and valve signals; loose or burnt connections cause failures.

Failure symptoms: intermittent operation, overheated or blackened terminals, loss of a speed.

What to check: relay coil voltage and contact current (A), terminal cross-section.
Generic
Ask about this part →

Fan coil controller and thermostat types

The part that controls the fan coil on the user side is the controller or room thermostat. When it is replaced, the new controller must match the unit's motor type, pipe system and valve arrangement.

TypeFeaturesWhere is it suitable?
Mechanical thermostatRotary setting, 3-speed fan switch, heating/cooling selectorSimple units with 3-speed AC motors
Digital thermostatDisplay, precise temperature control, automatic fan speed; weekly programming on some modelsOffices, hotels, homes; replacing mechanical thermostats
EC motor compatible thermostatStepless speed control via a 0–10 V fan outputFan coils with EC motors
Wi-Fi / smart thermostatRemote control and programming from a phoneHomes, villas, small offices
Wireless (IR) remote controlWorks with the receiver on the unit; usually specific to the unit's brandCassette and wall-mounted units
On-unit control panelThe controls are located directly on the unit casingCabinet floor-standing and wall-mounted units
Networked thermostat and central panelConnects to building automation via Modbus, BACnet or KNX; many units are managed from a single pointHotels, hospitals, office towers, public buildings

Controller wiring and connection

Brand-specific controllers

On some brands the controller works together with the unit's own control board and is brand-specific. For these units an original controller or a solution compatible with the board is chosen; on simple 3-speed units, general-purpose thermostats such as Siemens, Honeywell or Schneider Electric can be used. Controller sections on our brand pages: Daikin, Aermec, Alarko Carrier, Galletti, McQuay, Aldağ.

Guides (in Turkish): thermostat wiring diagram, Wi-Fi smart thermostat, Siemens RDF thermostat, Daikin fan coil controller, Aldağ thermostat and controller, remote control not responding, thermostat prices.

Drainage

Condensate drain pan

Collects the condensate that drips from the coil during cooling.

Failure symptoms: overflowing, stains on the ceiling, odour, rust or holes.

What to check: model-specific dimensions; galvanised, stainless or plastic; insulated or not.
OEM
Ask about this part →

Condensate (drain) pump

Pumps the condensate away where it cannot drain by gravity.

Failure symptoms: pump not running or running constantly, overflow, unit stopped by the alarm.

What to check: flow rate (l/h), discharge head (m), suitable cooling capacity (kW), noise level, 230 V, alarm contact.
SauermannAspen PumpsCharles Austen (Blue Diamond)
Ask about this part →

Float switch / overflow alarm

Starts the pump or stops the unit when the water level in the pan rises.

Failure symptoms: alarm permanently active, pump does not kick in.

What to check: contact type (NC/NO), contact current, mounting method.
SauermannAspen PumpsCharles Austen (Blue Diamond)
Ask about this part →

Air side and casing

Fan coil filter

Protects the coil and fan from dust and improves indoor air quality.

Failure symptoms: reduced airflow, dirty coil, odour.

What to check: class (ISO 16890 coarse / former G2–G3–G4), size (mm), thickness, washable or disposable, frame type. Can be cut to size.
Generic
Ask about this part →

Coil (heat exchanger)

Transfers heat between the water and the air.

Failure symptoms: water leaks, crushed and dirty fins, frost cracks, loss of capacity.

What to check: number of rows, tube diameter, fin spacing, connection side (right/left), 2-pipe or 4-pipe, capacity (kW).
OEM
Ask about this part →

Electric heater

Used in some fan coils as an additional or sole heat source.

Failure symptoms: no heating, safety thermostat tripping, burning smell.

What to check: power (W), voltage, safety thermostat.
OEM
Ask about this part →

Cassette panel and grille

Distributes air in four directions on cassette units.

Failure symptoms: broken grille, panel that will not close, yellowed surface.

What to check: panel size and unit model.
OEM
Ask about this part →

Louvre (swing) motor

Moves the air discharge louvres on cassette and wall-mounted units.

Failure symptoms: louvres not moving, grinding noise.

What to check: voltage (12 V DC stepper or 230 V synchronous), rpm, shaft type.
OEM
Ask about this part →

Plenum, diffuser and duct connection

Carries air from a concealed ceiling unit into the ductwork and grilles.

Failure symptoms: air leakage, noise, condensation.

What to check: flange size, duct diameter, insulation.
Generic
Ask about this part →

Pipe and valve insulation

Prevents condensation and heat loss on chilled water pipes and valves.

Failure symptoms: sweating and dripping on pipes, valves or the ceiling.

What to check: thickness (mm), elastomeric rubber foam, fire rating.
Generic
Ask about this part →

Can't find your part in the list?

Send us a photo; we also source and supply parts that are not listed here.

Message us on WhatsApp →

Commonly used spare part brands

Alongside original parts, products from the manufacturers below are widely used in fan coils for components such as valves, actuators, thermostats, motors and pumps. We select parts according to your unit's technical values.

Watts

Motorized valve bodies and thermoelectric / electromechanical actuators

Siemens

VVP47 / VXP47 valves, STA/STP actuators, RDF / RDG fan coil thermostats

Honeywell

VC series zone valves and actuators, fan coil thermostats

Belimo

ZoneTight QCV valves and CQ actuators

Danfoss

AB-QM pressure-independent balancing and control valves, TWA thermal actuators

Schneider Electric

SpaceLogic SE8000 fan coil thermostats

Smallart

Mechanical and digital fan coil thermostats

ebm-papst

EC fans for fan coil applications

Ziehl-Abegg

EC motor fans

Fergas

Fan coil fan motors and blower wheels

Ducati Energia

Motor capacitors

Euromotors

Fan coil speed transformers

Caleffi

Automatic air vents

Sauermann

Mini condensate pumps

Aspen Pumps

Mini condensate pumps

Charles Austen (Blue Diamond)

Tank-type condensate pumps

DDC-Tech

Fan coil valve bodies and actuators

E.C.A.

Motorized fan coil valve sets

Fan coil spare parts by brand

Choose your unit's brand; the brand page covers its series, error codes and controllers.

All brands →

What to send for part matching

To find the right part first time, send the information below together with photos of the rating plate and the old part. Leave out any values you don't know; the label on the part itself is often enough.

PartWhat to send
Fan motorMotor label code; single or double shaft; shaft diameter and length; body diameter; number of AC speeds or EC; power (W); direction of rotation; supply voltage; number and colours of wires
CapacitorCapacitance (µF), voltage (V), connection type (wired or plug-in), body size
Motorized valve bodyConnection size (DN / inch), Kvs value, 2-way or 3-way (4-port), thread type, body brand
Actuator (valve motor)Supply voltage (230 V / 24 V), normally closed (NC) or normally open (NO), on/off or modulating (0–10 V), connection adapter, cable length
Thermostat / controller2-pipe or 4-pipe; number of fan speeds or EC (0–10 V); supply (230 V / 24 V); valve output (on/off / 0–10 V); summer/winter changeover (manual / automatic); flush or surface mounted; communication requirement (Modbus, BACnet, KNX)
Condensate pumpPump model, flow rate, lift height, float and alarm contact, supply voltage
Control boardCode and label on the board, photos of both sides of the board, connected controller model
FilterWidth × height × thickness, filter class (G2 / G3 / G4), frame type
CoilNumber of rows, fin length and height, tube diameter, connection side (right / left), 2-pipe or 4-pipe
Blower wheelWheel diameter and width, hub (shaft) diameter, direction of rotation, number of scrolls
The easiest way: send the photos on WhatsApp; we will reply in writing with the matching original or equivalent part, its price and delivery time.

How to order

StepWhat happens
1. PhotoYou send a photo of the unit's rating plate and the part to be replaced.
2. MatchingWe identify the original or equivalent part from the make, model and technical values.
3. QuotationPrice, lead time and any difference for an equivalent part are sent to you in writing.
4. Delivery / fittingThe part is shipped by courier, or fitted and tested by our team.
Product and brand names belong to their respective owners. Drawings are illustrative; the actual appearance of a part varies by manufacturer and model.

Frequently asked questions

What should be checked when replacing a fan coil motor?

Power (W), number of speeds, rpm, shaft diameter and number of shafts, direction of rotation and capacitor value must all match. For EC motors, compatibility of the control signal (0–10 V / PWM) is also checked.

How can I tell whether the motorized valve or the actuator has failed?

If water flows when the actuator is opened manually, the problem is usually the actuator. If water does not flow even when opened manually, the valve body may be blocked or seized.

Can I replace the thermostat with a different brand?

Yes. A thermostat of a different brand can be used as long as the 2/4-pipe configuration, valve type, motor speeds and supply voltage are compatible.

How is a condensate pump selected?

It is selected according to flow rate (l/h), discharge head and the unit's cooling capacity. If it has an alarm contact, it should be connected to the unit's control circuit.

Do you ship parts outside Ankara?

Yes, we ship parts by courier anywhere in Turkey.