About Airfel fan coils
Origin: Türkiye (part of Daikin since 2011). In Türkiye: Older Airfel fan coils were made in Hendek; the current catalog has no fan coils, so service covers existing units.
We service all Airfel fan coil models produced over the years, based on the information on the unit's rating label.
Unit types
Our services for Airfel fan coils
Airfel fan coil maintenance
Checks of filters, coil, drain pan, drainage, fan, valves and thermostat; documented periodic maintenance.
Airfel fan coil faults and repair
On-site repair of water leaks, no cooling, fans not turning, valve and controller faults.
Cleaning and filters
Chemical coil washing, drain pan disinfection, filters cut to size.
Airfel fan coil spare parts
Supply and fitting of compatible motors, valves, thermostats, pumps and other parts.
Airfel fan coil error codes
Most Airfel fan coils run on a 3-speed motor and a simple room thermostat; the manufacturer has not published an error code list for these units. Faults are diagnosed from symptoms and measurements. In projects using an electronic controller or networked thermostat, the codes depend on the controller's own brand.
| Symptom | Possible cause | Details |
|---|---|---|
| Water leaking | Blocked drain, overflowing or cracked drain pan, sweating valve | Fix |
| Cassette condensate pump alarm | Float switch or pump fault, blocked drain | Pump |
| No cooling / no heating | Stuck motorized valve, air in the coil, dirty filter | Fix |
| Fan not turning | Capacitor, motor or speed control | Fix |
| Noise and vibration | Dirty or unbalanced fan wheel, bearing | Fix |
| Weak airflow (ducted type) | Dirty filter, duct connection, low fan speed | Cleaning |
Common thermostat warnings
Warnings shown on Siemens RDF series thermostats, which are often used with Airfel fan coils:
| Indication | Meaning | What to do |
|---|---|---|
| AL1 | External fault input X1 active (e.g. drain alarm) | Check the device connected to input X1. |
| AL2 | External fault input X2 active | Check the device connected to input X2. |
| FIL | Filter cleaning reminder | Clean the filter and reset the warning. |
| Dew (condensation) symbol | Condensation detected in the room, cooling stopped | Check humidity and water temperature. |
Is your Airfel fan coil showing a code?
Send a photo of the controller display and the unit's rating label and we will interpret it right away.
Airfel fan coil controllers and thermostats
On Airfel fan coils we replace faulty or outdated thermostats with new models suited to the unit's 2/4-pipe configuration, valve type and motor speeds: mechanical, digital, weekly programmable and Modbus / BACnet / KNX networked options. Thermostat options →
Airfel fan coil spare parts
Airfel fan coil motor
Compatible part supply and fitting
Airfel capacitor
Compatible part supply and fitting
Airfel fan wheel
Compatible part supply and fitting
Airfel motorized valve
Compatible part supply and fitting
Airfel actuator
Compatible part supply and fitting
Airfel thermostat
Compatible part supply and fitting
Full spare parts catalog (28 parts) →
Airfel fan coil service in Ankara
We service Airfel fan coils on-site in every district of Ankara. We prepare bulk maintenance plans for office towers, hospitals, hotels, schools, shopping malls and residential complexes. For Airfel units outside Ankara, we start with a pre-diagnosis from photos and videos, followed by a scheduled visit with the required parts.
Fan coil service for other brands
Aldağ fan coil service
Üntes fan coil service
Daikin fan coil service
Carrier fan coil service
Form fan coil service
Systemair fan coil service
Mitsubishi Electric fan coil service
Arçelik fan coil service
Ventas fan coil serviceTeknogenTeknogen fan coil serviceFrequently asked questions
Do you service Airfel fan coils on-site in Ankara?
Yes. Our base is in Etimesgut; we carry out on-site maintenance, fault repair and part replacement on Airfel fan coils in every district of Ankara. For Airfel units outside Ankara we provide scheduled service across Türkiye.
Are you the authorized Airfel service?
No. YOİ Mühendislik is an independent service holding the TSE Service Adequacy Certificate (HYB No: 12850); we service all brands, including Airfel, independently of the manufacturer. For units still under warranty, we recommend checking the manufacturer's terms first.
What does a Airfel fan coil error code mean?
Many Airfel fan coils are 3-speed units with a simple thermostat and have no published error code list. If you see a code on the display of a model with an electronic controller, send us a photo and we will interpret it based on the controller and board model.
Are Airfel fan coil spare parts available?
For parts such as motors, capacitors, motorized valves, actuators, thermostats, drain pans, condensate pumps, filters and fan wheels, we supply original parts that fit Airfel units or equivalents whose technical ratings match exactly. A photo of the rating label is enough.
How often should Airfel fan coils be serviced?
A full service at least twice a year, before the cooling and heating seasons; filter checks are recommended every 1–3 months depending on usage.