Home›Knowledge Center›Brands›Clivet Fan Coil Service

Clivet fan coil service Ankara

On-site service in Ankara and scheduled service across Türkiye for the maintenance, fault repair, controls and spare parts of your Clivet fan coils. We service all Clivet fan coil models independently of the manufacturer.

  • Symptom-based diagnosis
  • Controls and thermostats
  • Compatible spare parts
  • On-site in Ankara
Please note: YOİ Mühendislik is not the manufacturer's authorized service for Clivet. As an independent service holding the TSE Service Adequacy Certificate (HYB No: 12850), we provide maintenance, repair and spare parts for Clivet fan coils. The brand name is used only to indicate equipment compatibility and belongs to its owner.

About Clivet fan coils

Origin: Italy. In Türkiye: Imported; units installed in various projects.

We service all Clivet fan coil models produced over the years, based on the information on the unit's rating label.

Unit types

Our services for Clivet fan coils

Clivet fan coil error codes

Most Clivet fan coils run on a 3-speed motor and a simple room thermostat; the manufacturer has not published an error code list for these units. Faults are diagnosed from symptoms and measurements. In projects using an electronic controller or networked thermostat, the codes depend on the controller's own brand.

SymptomPossible causeDetails
Water leakingBlocked drain, overflowing or cracked drain pan, sweating valveFix
Cassette condensate pump alarmFloat switch or pump fault, blocked drainPump
No cooling / no heatingStuck motorized valve, air in the coil, dirty filterFix
Fan not turningCapacitor, motor or speed controlFix
Noise and vibrationDirty or unbalanced fan wheel, bearingFix
Weak airflow (ducted type)Dirty filter, duct connection, low fan speedCleaning

Common thermostat warnings

Warnings shown on Siemens RDF series thermostats, which are often used with Clivet fan coils:

IndicationMeaningWhat to do
AL1External fault input X1 active (e.g. drain alarm)Check the device connected to input X1.
AL2External fault input X2 activeCheck the device connected to input X2.
FILFilter cleaning reminderClean the filter and reset the warning.
Dew (condensation) symbolCondensation detected in the room, cooling stoppedCheck humidity and water temperature.

Is your Clivet fan coil showing a code?

Send a photo of the controller display and the unit's rating label and we will interpret it right away.

Message us on WhatsApp →

Clivet fan coil controllers and thermostats

On Clivet fan coils we replace faulty or outdated thermostats with new models suited to the unit's 2/4-pipe configuration, valve type and motor speeds: mechanical, digital, weekly programmable and Modbus / BACnet / KNX networked options. Thermostat options →

Clivet fan coil spare parts

Full spare parts catalog (28 parts) →

Clivet fan coil service in Ankara

We service Clivet fan coils on-site in every district of Ankara. We prepare bulk maintenance plans for office towers, hospitals, hotels, schools, shopping malls and residential complexes. For Clivet units outside Ankara, we start with a pre-diagnosis from photos and videos, followed by a scheduled visit with the required parts.

For more information on Clivet fan coil maintenance, see the Clivet fan coil service and maintenance page on the main YOİ Mühendislik website (in Turkish).

Fan coil service for other brands

All brands →

Frequently asked questions

Do you service Clivet fan coils on-site in Ankara?

Yes. Our base is in Etimesgut; we carry out on-site maintenance, fault repair and part replacement on Clivet fan coils in every district of Ankara. For Clivet units outside Ankara we provide scheduled service across Türkiye.

Are you the authorized Clivet service?

No. YOİ Mühendislik is an independent service holding the TSE Service Adequacy Certificate (HYB No: 12850); we service all brands, including Clivet, independently of the manufacturer. For units still under warranty, we recommend checking the manufacturer's terms first.

What does a Clivet fan coil error code mean?

Many Clivet fan coils are 3-speed units with a simple thermostat and have no published error code list. If you see a code on the display of a model with an electronic controller, send us a photo and we will interpret it based on the controller and board model.

Are Clivet fan coil spare parts available?

For parts such as motors, capacitors, motorized valves, actuators, thermostats, drain pans, condensate pumps, filters and fan wheels, we supply original parts that fit Clivet units or equivalents whose technical ratings match exactly. A photo of the rating label is enough.

How often should Clivet fan coils be serviced?

A full service at least twice a year, before the cooling and heating seasons; filter checks are recommended every 1–3 months depending on usage.